BIO RAD 400-0174 Provozní pokyny Strana 417

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 485
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 416
Error Messages
Message Meaning Possible cause
SmartDrive
Limp modeCheck Remedy
Short circuit/broken cable in wiring for
coil
Check wiring to valve
Coil defective Replace coil
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in wiring for
coil
Check wiring to valve
Coil defective Replace coil
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in wiring for
coil
Check wiring to valve
Coil defective Replace coil
SmartDrive pump
1 coil 2 (Y1)
Error: Coil 2
Pu
mp 1
48 SmartDrive pump
2 coil 1 (Y4)
Error: Coil 1
Pump 2
46 SmartDrive pump
1 coil 1 (Y2)
Error: Coil 1
Pu
mp 1
47
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in wiring for
coil
Check wiring to valve
Coil defective Replace coil
Internal SmartDrive error Replace SmartDrive
Perform joystick diagnostics
Power supply voltage
Joystick defective
Check fuse -22-F57
Ch
eck fuse -22-F65
Power supply voltage
central electrical system defective
LED -22-LD31 not lit Check fuse -22-F77
LED -22-LD63 not lit Check fuse -22-F63
Check fuse -22-F92
Driving lever defective Replace driving lever
Internal SmartDrive error Replace SmartDrive
49 SmartDrive pump
2 coil 2 (Y3)
Error: Coil 2
Pu
mp 2
50 SmartDrive
joystick error
Error:
The driving lever signal
incorrect/defective
Zobrazit stránku 416
1 2 ... 412 413 414 415 416 417 418 419 420 421 422 ... 484 485

Komentáře k této Příručce

Žádné komentáře