Maintenance – electrical system
382
Pos: 34.5 /Übersc hriften/Übersc hriften 2/A-E/B atterie @ 0\mo d_119736652 0558_78.doc @ 18648
17.2 Battery
Pos: 34.6 /BA/Sich erheit/Gefahr enhinweise/Batt eriegase sind hoc hexplosiv @ 0\mod_1197 366598276_78. doc @ 18667
Danger!
Battery gases are highly explosive
Effect: Danger to life, injuries or damage to the machine.
• Batteries develop a highly explosive electrolytic gas. Do not allow
sparks or naked flames anywhere near the battery.
• During repair work (welding work) on the electrical system or engine,
always switch the engine off.
• Interrupt the electrical power circuit with the main battery switch.
• Disconnect the cable plug (2) from the MR2 control unit on the engine!
• Note the correct polarity when disconnecting and connecting the
battery.
• When jump-starting the battery, make certain that only a voltage of 12 V
is connected to each battery!
Pos: 34.7 /BA/W artung/Selbstfa hrer/Wartung - Elektrik/Batteri en Big M 400 @ 0\mod_11973 67396698_78. doc @ 18749
Fig. 333:
The Big M II is equipped with two batteries (1) of 12 V (135 Ah) each, which are connected in
series (24 V) for starting.
A switching relay (2) is used to switch.
The operating voltage is only 12 V!
Note
Keep the battery clean of dust and chaff.